Security engines
Log centralisation
Your own log store is read for the security events in it. Every rule that fires becomes a detection on your record, with the rule's own severity.

- minutes between runs
60
The connection is read every hour, and again on Sync now.
- severity levels
5
Informational, low, medium, high and critical, taken from the rule itself.
- detector per log source
1
One detector for each kind of log, running its built-in rules.
What TruSecure does
Your log store, and the rules that watch it
The engine reads the kinds of log your log store knows. You switch a kind on with the index that holds those logs. The engine then makes a detector for it, running the store's own rules at the levels and the rate you chose.
The run
What a read of the log store does
On your schedule, or when a person presses Sync now, the log store is read in four steps.
| Step | What happens |
|---|---|
| Prepares the tool | It signs in to the log store and reads the kinds of log it knows, into your log sources, each switched off. You switch a source on with the index that holds those logs. |
| Reads | It reads back what the detectors found. Every time a rule matched a log line is one finding of the log store's, and the findings of one detector and one rule are one detection of yours. |
| Writes back | It writes each source you switched on: the field mappings the log store suggests for that index, and a detector running the built-in rules at the levels you chose. A source switched off has its detector switched off, never deleted. |
| Records the run | Each detection keeps the rule, its severity, how many times it matched and where it was found. The matched log lines stay in the log store. |
Questions
Questions we are asked about your logs
- Where do the log lines live?
- In your own log store, which the engine never copies. A detection keeps the rule, its severity, its count and its index. The lines stay where your systems sent them.
- What if the log store cannot be reached?
- The run tells you what went wrong in one sentence, and your detections stay as they were. A sync that could not read every page of findings writes nothing, so a detection is never half counted.
- Which logs are watched?
- Only the kinds you switch on, each with the index that holds those logs. Each one gets its own detector, running the built-in rules at the levels and the rate you chose.
- What happens when I switch a source off?
- Its detector is switched off and never deleted. The detections it already raised stay on your record with their counts.
Open source
This capability runs OpenSearch Security Analytics, an open-source project released under the Apache-2.0 licence.
Start
See what your own logs already show
Tell us where your logs are kept. We show you which detection rules would be switched on, and what each one would find.